Calculate impedance for inner layer traces

Trace Parameters

Reference Plane 1
H1
Dielectric
Signal (W × T)
H2
Dielectric
Reference Plane 2

Results

Symmetric Stripline Impedance (Z0)

51.56Ω

Propagation Delay

179.73 ps/in

Wavelength

141.32 mm

Velocity

141.3 km/s

Capacitance

3.486 pF/in

Inductance

9.267 nH/in

Stripline vs Microstrip

Shielding

Better EMI immunity with two reference planes

Crosstalk

Lower crosstalk than microstrip

Propagation

Slower due to full Er (not effective Er)

Design Tips

  • Use symmetric stripline when possible for best performance
  • Ideal for high-speed signals requiring shielding
  • Requires via transitions for component connection

Need PCB Manufacturing?

We offer controlled impedance manufacturing.

Get Free Quote

Method, assumptions & worked example

Formula used by this calculator

Symmetric (H1 = H2): b = H1 + H2 + T, x = T / b

Z0 = 30/√εr · ln{1 + (4/π)·A·[(8/π)·A + √((8/π·A)² + 6.27)]}, A = (b − T) / W′

W′ = W + ΔW, ΔW = (b − T) · x/(π(1 − x)) · {1 − ½·ln[(x/(2 − x))² + (0.0796x / (W/b + 1.1x))^m]}, m = 2 / (1 + (2/3)·x/(1 − x))

Offset (H1 ≠ H2): Z0 = 2·Z1·Z2 / (Z1 + Z2), with Z1, Z2 the symmetric result for b = 2·H1 + T and b = 2·H2 + T

t_pd = √εr / c

W
trace width
H1, H2
dielectric thickness above and below the trace
T
copper thickness
b
plane-to-plane spacing
W′
width corrected for copper thickness
εr
dielectric constant

Source: Symmetric stripline: H. A. Wheeler, “Transmission-line properties of a strip line between parallel planes”, IEEE Trans. Microwave Theory Tech., vol. 26, no. 11, 1978, as given in Wadell, Transmission Line Design Handbook (1991), ch. 3. Offset stripline as two half-lines in parallel: Johnson & Graham, High-Speed Digital Design (1993), Appendix C.

Assumptions & limits

  • Symmetric case: the closed form is quoted as accurate to about 0.5 % for W′/(b − T) < 10. Against a 2-D field solution it stayed within 0.5 % for the default geometry and within 3 % for the thick-copper cases we checked.
  • Offset case: the parallel combination is exact when H1 = H2 and reads high as the trace moves off-centre, by up to about 6 % in the cases we checked (W = 4, T = 0.7, H1 = 4, H2 = 20 mil gives 56.2 Ω against 52.8 Ω from the field solution). Use a field solver for strongly offset or dual-stripline stack-ups.
  • No result is shown when W is more than 10 times, or T more than 1.4 times, twice the smaller dielectric height.
  • Signal travels fully in the dielectric, so ε_eff = εr.
  • Prepreg and core can have different εr; the formula assumes one homogeneous value.

Worked example (the calculator's default inputs)

Inputs: W = 5 mil · H1 = H2 = 8 mil · T = 1.4 mil · εr = 4.5

  1. b = 8 + 8 + 1.4 = 17.4 mil, x = 1.4 / 17.4 = 0.0805.
  2. m = 1.890, ΔW = 1.808 mil, W′ = 6.808 mil, A = 16 / 6.808 = 2.350.
  3. Z0 = 30/√4.5 · ln(1 + 2.992 · (5.985 + 6.487)) = 14.142 · 3.646 = 51.6 Ω.
  4. Delay = √4.5 / c = 179.7 ps/inch.

Result: Z0 ≈ 51.6 Ω, about 180 ps/inch — close to a 50 Ω inner-layer target.

Figures are calculated with the formula above, not measured. Field-solver tools and your fabricator's stack-up data take priority for production impedance and current limits.