Annular Ring Calculator
Calculate via and pad annular ring width
Input Parameters
Tolerance on the hole diameter. Half of it comes off the ring on each side.
How far the hole centre can sit from the pad centre. All of it comes off the ring on the tight side.
Results
Worst-case ring 0.125 mm against a 0.050 mm (2.0 mil) design target.
This is a design-margin check, not an acceptance verdict. IPC-6012 Class 2 accepts hole breakout of up to 90° from the land, so a finished board can be accepted below this design target.
Nominal Annular Ring
0.200 mm
7.9 mil
Worst Case Ring
0.125 mm
4.9 mil
IPC Requirements
Class 1 (General)
Hole breakout of up to 180° is accepted
Class 2 (Dedicated)
Hole breakout of up to 90° is accepted
Class 3 (High Rel)
No breakout. Min: 0.05 mm (2 mil) external, 0.025 mm (1 mil) internal
Finished-board acceptance for plated holes in IPC-6012, summarised. Extra conditions apply where breakout is allowed, and the wording changes between revisions, so the revision on your drawing governs. The calculator itself checks one 0.05 mm design target.
Best Practices
- Design for worst-case tolerances
- Add margin for manufacturing variation
- Consider pad size early in design
Method, assumptions & worked example
Formula used by this calculator
AR_nom = (D_pad − D_hole) / 2
AR_worst = (D_pad − (D_hole + T_hole)) / 2 − T_reg
D_pad,min = (D_hole + T_hole) + 2·(0.05 mm + T_reg)
- D_pad
- finished pad (land) diameter
- D_hole
- nominal hole (drill) diameter
- T_hole
- hole-size tolerance, on the diameter (a ±0.05 mm hole can be 0.05 mm larger)
- T_reg
- registration tolerance, radial (how far the hole centre can sit from the pad centre)
Source: Land-size relation from IPC-2221 (Generic Standard on Printed Board Design), land requirements: minimum land = maximum hole diameter + 2 × minimum annular ring + fabrication allowance. Finished-board acceptance of annular ring and breakout: IPC-6012 (Qualification and Performance Specification for Rigid Printed Boards). Tolerances should come from your fabricator’s capability sheet.
Assumptions & limits
- The result is a design-margin check against one 0.05 mm (≈2 mil) target. It is not an IPC class verdict: IPC-6012 acceptance depends on class, on external versus internal layers and on the revision your drawing calls out, and Classes 1 and 2 accept limited breakout.
- The hole tolerance is taken on the diameter, so half of it is lost per side; the registration tolerance is taken as a radial shift, so all of it is lost on the tight side.
- Tolerances are added linearly (worst-case stack-up), which is more conservative than a statistical (RSS) stack-up.
- Plating thickness, etch-back and pad undercut are not modelled. On external layers the ring is measured from the plated hole wall.
Worked example (the calculator's default inputs)
Inputs: Pad 0.70 mm · Hole 0.30 mm · Hole tolerance ±0.05 mm · Registration tolerance ±0.05 mm
- AR_nom = (0.70 − 0.30) / 2 = 0.200 mm (7.9 mil)
- AR_worst = (0.70 − 0.35) / 2 − 0.05 = 0.125 mm (4.9 mil)
- 0.125 mm ≥ 0.05 mm design target → MET
- Smallest pad that still meets the target: 0.35 + 2 × (0.05 + 0.05) = 0.55 mm
Result: Nominal ring 0.200 mm, worst case 0.125 mm (meets the 0.05 mm design target); minimum pad 0.55 mm
Figures are calculated with the formula above, not measured. Field-solver tools and your fabricator's stack-up data take priority for production impedance and current limits.